Name
DTMF
Code
Description Default
Door
Control
Open Code **31 LL S… LL = length of string (00 to 04)
S… = numeric string (e.g. **31016 = “6”)
Digit 6
Relay Time **32 nn nn=00: ¼ second nn=01..30: 1-30 seconds 3 sec
Cancel with Door
Open
**33 nn nn=00: No
nn=01: Yes
00 No
Latch Open Code **34 LL S… LL = length of string (00 to 04)
S… = numeric string (e.g. **34017 = “7”)
None
Release Code **35 LL S… LL = length of string (00 to 04)
S… = numeric string (e.g. **35018 = “8”)
None
Auxiliary
I/O
Controller Output **41 nn nn=00: In-Use
nn=01: Ring
nn=02: Call Button Press
nn=03: Door Control
nn=04: Door Sensor
nn=05: Door Alarm
nn=06: Follow
Controller Input
nn=07: Follow Station Input
nn=08: Disabled
00 In-Use
Door Station
Output
**42 nn nn=00: In-Use
nn=01: Ring
nn=02: Call Button Press
nn=03: Door Control
nn=04: Door Sensor
nn=05: Door Alarm
nn=06: Follow Controller
Input
nn=07: Follow Station Input
nn=08: Disabled
02 Call
Button
Press
Door Relay **43 nn nn=00: In-Use
nn=01: Ring
nn=02: Call Button Press
nn=03: Door Control
nn=04: Door Sensor
nn=05: Door Alarm
nn=06: Follow Controller
Input
nn=07: Follow Station
Input
nn=08: Disabled
03 Door
Control
Controller Input **44 nn nn=00: Door Sensor, Normally Open Input
nn=01: Door Sensor, Normally Closed Input
nn=02: Manual Door Release Input
nn=03: Door Control Lockout Input
nn=04: Call Button, Normally Open Input
nn=05: Call Button, Normally Closed Input
nn=06: Disabled
01 Door
Sensor NC
Door Station Input **45 nn nn=00: Door Sensor, Normally Open Input
nn=01: Door Sensor, Normally Closed Input
nn=02: Call Button, Normally Open Input
nn=03: Call Button, Normally Closed Input
nn=04: Disabled
02 Call
Button NO